go-eShop cookies policy

This shop uses cookies for technical reasons and to provide you with the best possible experience. Continued use of the shop indicates that you accept this policy. ()

Circuit breaker 32A 3P+N

Item number: CH-10-01

Circuit breaker with three phases plus neutral circuit.

including20% VAT., plus shipping (Klein)

Available now!

Shipping time: 2 - 3 workdays



Description

Main
device application
Distribution
range
Acti 9
product name
Acti 9 iC60
product or component type
Miniature circuit-breaker
device short name
IC60N
poles description
4P
number of protected poles
4
[In] rated current
32 A
network type
AC
DC
trip unit technology
Thermal-magnetic
curve code
C
breaking capacity
6 kA Icu conforming to EN/IEC 60947-2 ? 440 V AC 50/60 Hz
10 kA Icu conforming to EN/IEC 60947-2 ? 380?415 V AC 50/60 Hz
20 kA Icu conforming to EN/IEC 60947-2 ? 220?240 V AC 50/60 Hz
10 kA Icu conforming to EN/IEC 60947-2 ? <= 250 V DC
6000 A Icn conforming to EN/IEC 60898-1 ? 400 V AC 50/60 Hz
36 kA Icu conforming to EN/IEC 60947-2 ? 12?60 V AC 50/60 Hz
36 kA Icu conforming to EN/IEC 60947-2 ? 100?133 V AC 50/60 Hz
utilisation category
Category A conforming to EN 60898-1
Category A conforming to IEC 60898-1
suitability for isolation
Yes conforming to EN 60947-2
Yes conforming to IEC 60947-2
Yes conforming to EN 60898-1
Yes conforming to IEC 60898-1
standards
EN 60898-1
EN 60947-2
IEC 60947-2
IEC 60898-1
Complementary
network frequency
50/60 Hz
magnetic tripping limit
8 x In +/- 20 %
[Ics] rated service breaking capacity
6000 A 100 % x Icu conforming to IEC 60898-1 ? 400 V AC 50/60 Hz
10 kA 100 % x Icu conforming to IEC 60947-2 ? 180?250 V DC
10 kA 100 % x Icu conforming to EN 60947-2 ? 180?250 V DC
6000 A 100 % x Icu conforming to EN 60898-1 ? 400 V AC 50/60 Hz
4.5 kA 75 % x Icu conforming to IEC 60947-2 ? 440 V AC 50/60 Hz
15 kA 75 % x Icu conforming to EN 60947-2 ? 220?240 V AC 50/60 Hz
7.5 kA 75 % x Icu conforming to EN 60947-2 ? 380?415 V AC 50/60 Hz
4.5 kA 75 % x Icu conforming to EN 60947-2 ? 440 V AC 50/60 Hz
15 kA 75 % x Icu conforming to IEC 60947-2 ? 220?240 V AC 50/60 Hz
7.5 kA 75 % x Icu conforming to IEC 60947-2 ? 380?415 V AC 50/60 Hz
27 kA 75 % x Icu conforming to IEC 60947-2 ? 12?133 V AC 50/60 Hz
27 kA 75 % x Icu conforming to EN 60947-2 ? 12?133 V AC 50/60 Hz
limitation class
3 conforming to EN 60898-1
3 conforming to IEC 60898-1
[Ui] rated insulation voltage
500 V AC 50/60 Hz conforming to IEC 60947-2
500 V AC 50/60 Hz conforming to EN 60947-2
[Uimp] rated impulse withstand voltage
6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2
contact position indicator
Yes
control type
Toggle
local signalling
Trip indicator
mounting support
DIN rail
9 mm pitches
8
height
91 mm
width
72 mm
depth
78.5 mm
Shipping weight: 0,80 Kg
Product weight: 0,30 Kg

Ratings (0)

Average product review

Write your first review and help others with their purchase decision:

Product Tags

Please login first to add a tag.