Miniature circuit breaker 16 A 3P+N
Miniature circuit breaker 16 A 3P+N

Miniature circuit breaker 16 A 3P+N

Article no.: CH-10-02

Miniature circuit breaker iC60N with three phases plus neutral circuit, 16 A, characteristic B

37,90 €
incl. VAT., plus shipping costs
Average delivery time: 7 Days

Piece:
Add to shopping basket

Miniature circuit-breaker 16 A 3P+N

The circuit to which the go-e Charger is to be connected must be equipped with a miniature circuit breaker (characteristic B or C) of the following specification:

  • Connection 16 A or 32 A three-phase = 3- or 4-pole miniature circuit breaker for 16 A or 32 A.
  • Connection 16 A or 32 A single-phase = 2-pole miniature circuitbreaker for 16 or 32 A

The miniature circuit breaker offered here is suitable for the three-phase connection of the go-e Charger with a maximum of 16 A.

Mounting

  • Protection class (IP): IP20 complies with EN/IEC 60529
  • Pollution degree: 3
  • Overvoltage category: IV
  • Relative humidity: 95 % at 55 °C
  • Ambient temperature during operation: -35...70 °C
  • Ambient temperature during storage: -40...85 °C

Main Features

  • Series/Product name: Acti 9 iC60N
  • Product or component type: Miniature circuit breaker
  • Pole description: 3P+N
  • Neutral position: Left
  • Rated current: 16 A
  • Network connection: AC / DC
  • Tripping unit technology: Thermomagnetic
  • Characteristic: B
  • Breaking capacity:
  • 6000 A Icn at 400 V AC 50/60 Hz complies with EN/IEC 60898-1
  • 36 kA Icu at 12-60 V AC 50/60 Hz complies with EN/IEC 60947-2
  • 10 kA Icu at 380-415 V AC 50/60 Hz complies with EN/IEC 60947-2
  • 20 kA Icu at 220-240 V AC 50/60 Hz complies with EN/IEC 60947-2
  • 6 kA Icu at 440 V AC 50/60 Hz complies with EN/IEC 60947-2
  • 36 kA Icu at 100-133 V AC 50/60 Hz complies with EN/IEC 60947-2
  • Application category: Category A complies with EN/IEC 60898-1
  • Suitability for insulation: Yes complies with EN/IEC 60898-1 and EN/IEC 60947-2

Additional features

  • Network frequency: 50/60 Hz
  • magnetic trip limit: 4 x In +/- 20 %
  • Rated trip current Ics:
  • 15 kA 75 % complies with EN/IEC 60947-2 - 220-240 V AC 50/60 Hz
  • 7.5 kA 75 % corresponds to EN/IEC 60947-2 - 380-415 V AC 50/60 Hz
  • 4.5 kA 75 % complies with EN/IEC 60947-2 - 440 V AC 50/60 Hz
  • 6000 A 100 % complies with EN/IEC 60898-1 - 400 V AC 50/60 Hz
  • 27 kA 75 % complies with EN/IEC 60947-2 - 12-133 V AC 50/60 Hz
  • Limitation class: 3 complies with EN/IEC 60898-1
  • Rated insulation voltage Ui: 500 V AC 50/60 Hz complies with EN/IEC 60947-2
  • Rated impulse withstand voltage [Uimp]: 6 kV complies with EN/IEC 60947-2
  • Positive contact indicator: Present
  • Type of actuation: Toggle switch
  • Local signalling: Trip indicator
  • Mounting bracket: DIN rail
  • 9 mm pitch: 8
  • Dimensions (height x width x depth): approx. 91 x 72 x 78.5 mm
  • Colour: white
  • Mechanical life: 20,000 cycles
  • Electrical life: 10,000 cycles
  • Connections - terminals: Double terminal, top or bottom fixed 1...25 mm² max. or double terminal, top or bottom flexible 1...16 mm² max.
  • Wire stripping length: 14 mm (top or bottom)
  • Tightening torque: 2 Nm (top or bottom)
  • Earth fault protection: Separate block